Two A International Co.,Ltd.

402, KGIT Center Worldcupbuk-Ro, Mapo-gu, Seoul, Republic of Korea Email. twoaintl@gmail.com / Tel. 02 2662 9745 / Fax. 02 2662 9746

  • Facebook

COVID-19​

Rapid Test Kit

- Made in Korea -

COVID-19 Rapid Test Kit is the One-Step  Reverse Transcription Real-Time PCR Kit designed to detect  Novel Corona virus (COVID-19) qualitatively through Reverse  Transcription reaction and Real-Time Polymerase Chain  Reaction
 

Rapid Diagnostic Kit

COVID-19 Real-Time PCR Kit

Process

· Target Genes : RdRp, N, E

· About 120 minutes detection for COIVD-19

· Reverse Transcription reaction and Real-Time Polymerase Chain Reaction

· Easy-to-use(One-Tube) and interpretation

· Reliable result by Internal/Positive/Negative Control

Kit Component
COVID-19 Rapid Test Kit

COVID-19

Reaction Mixture

1050 uL / kit

COVID-19

Probe Mixture

550 uL / kit

COVID-19

Positive Control

50 uL / kit

COVID-19

Negative Control

50 uL / kit

10 µl

Reaction Mixture

5 µl

Probe Mixture

5 µl

Sample RNA

Total 20 µl

Mixture / 1 sample

Instruments

Bio-Rad/CFX96

Applied Biosystems

7500 Real-time PCR System (ST/FAST)

COVID-19 Rapid Test Kit is validated on Bio-Rad CFX96 and  Thermo Fisher's AB7500 system (Standard/Fast).

If you are using other RT-PCR instruments, please contact us.

Analytic performance

Analytical Sensitivity  LOD(Limit of Detection)

Target

LoD

RdRp gene

10 copies/test

E gene

10 copies/test

N gene

10 copies/test

Analytical Specificity

No.

Name

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Influenza A (H1N1/09)

Influenza A (H3N2)

Influenza A (H5N1)

Influenza B

Rhinovirus

Respiratory syncytial virus (A/B)

Parainfluenza 1 virus

Parainfluenza 2 virus

Parainfluenza 3 virus

Parainfluenza 4 virus

Adenovirus

Human Bocavirus

Measles virus

Mycoplasma spp.

A total 14 DNA/RNA samples extracted from reference strains were tested on three  batches of the Rapid Test Kit in order to evaluate the  possibility of cross-reactivity.

The Negative control was detected as Not  applicable (N/A) (or undetermined, U.D)  which means there was no testing,  contamination and instrument errors.

14 DNA/RNA samples which have no concern with the detection target of the kit  were negative.

Clinical performance

Samples : Residual test samples from Laboratories with which the COVID-19 test was completed.

Type of sample: Extracted RNA from Nasopharyngeal swab, sputum.

CE13485 / GMP / CE (Declaration of conformity) / KFDA

Contact us for questions

TWO A International Co., Ltd. is an export partner of small and medium-sized enterprises. Our mission is to connect manufacturers and importers to minimize the trading stage and help them to sell and purchase products at reasonable prices.

We were established as a company in 2009 and converted into a corporation in 2014.